PRENSA-CABLE HEMBRA SIN ROSCA |
| |
| |
• Para utilizar cuando la salida de los cables fuere directa de los conductos eléctricos.
• Cubierta: se utiliza en área cubierta o aparente.
• A la intemperie: se utiliza a prueba de intemperie, polvo y vapor; aparente en área descubierta, empotrado en hormigonado.
(Se recomienda usar vaselina en la junta de estanqueidad). |
|
| |
|
|
|
CÓDIGO DEL CONDUCTO ELÉCTRICO
C = COMÚN
D = DIN 2440
S = SCHEDULE 40
PB = PVC CLASE B
PA = PVC CLASE A |
|
| |
SISTEMA |
TIPO DE CONDUCTO ELÉCTRICO |
TIPOS DE INSTALACIÓN Y CÓDIGO |
COMÚN - PVC/B
NBR 5624 - NBR 6150 |
Calibres |
Ø Agujero (mm) |
Dimensiones |
mm |
pol. |
min |
max |
A |
B |
C |
Cubierta |
A la intemperie |
15 |
1/2 |
7 |
10 |
50,0 |
21,1 |
34,5 |
PF 012 (C-PB) P |
PFT 012 (X) P |
15 |
1/2 |
10 |
15 |
50,0 |
21,1 |
34,5 |
PF 012 (C-PB) G |
PFT 012 (X) G |
20 |
3/4 |
7 |
15 |
58,0 |
26,2 |
40,0 |
PF 034 (C-PB) P |
PFT 034 (X) P |
20 |
3/4 |
15 |
20 |
58,0 |
26,2 |
40,0 |
PF 034 (C-PB) G |
PFT 034 (X) G |
25 |
1 |
13 |
15 |
69,0 |
33,2 |
51,0 |
PF 100 (C-PB) P |
PFT 100 (X) P |
25 |
1 |
15 |
22 |
69,0 |
33,2 |
51,0 |
PF 100 (C-PB) M |
PFT 100 (X) M |
25 |
1 |
22 |
25 |
69,0 |
33,2 |
51,0 |
PF 100 (C-PB) G |
PFT 100 (X) G |
32 |
1 1/4 |
19 |
28 |
83,0 |
42,2 |
59,5 |
PF 110 (C-PB) P |
PFT 110 (X) P |
32 |
1 1/4 |
28 |
34 |
83,0 |
42,2 |
59,5 |
PF 110 (C-PB) G |
PFT 110 (X) G |
40 |
1 1/2 |
19 |
28 |
99,0 |
47,8 |
72,5 |
PF 112 (C-PB) P |
PFT 112 (X) P |
40 |
1 1/2 |
34 |
38 |
99,0 |
47,8 |
72,5 |
PF 112 (C-PB) M |
PFT 112 (X) M |
40 |
1 1/2 |
38 |
40 |
99,0 |
47,8 |
72,5 |
PF 112 (C-PB) G |
PFT 112 (X) G |
50 |
2 |
22 |
38 |
111,0 |
59,4 |
87,5 |
PF 200 (C-PB) P |
PFT 200 (X) P |
50 |
2 |
38 |
47 |
111,0 |
59,4 |
87,5 |
PF 200 (C-PB) M |
PFT 200 (X) M |
50 |
2 |
47 |
50 |
111,0 |
59,4 |
87,5 |
PF 200 (C-PB) G |
PFT 200 (X) G |
65 |
2 1/2 |
52 |
54 |
125,0 |
75,1 |
103,5 |
PF 212 (C-PB) P |
PFT 212 (X) P |
65 |
2 1/2 |
54 |
62 |
125,0 |
75,1 |
103,5 |
PF 212 (C-PB) G |
PFT 212 (X) G |
65 |
2 1/2 |
- |
- |
- |
- |
- |
- |
- |
65 |
2 1/2 |
- |
- |
- |
- |
- |
- |
- |
|
|
| |
|
|
| |
TIPO DE CONDUCTO ELÉCTRICO |
TIPOS DE INSTALACIÓN Y CÓDIGO |
COMÚN - PVC/B
NBR 5624 - NBR 6150 |
Ø Agujero (mm) |
Dimensiones |
min |
max |
A |
B |
C |
Cubierta |
A la intemperie |
7 |
10 |
50,0 |
21,3 |
34,5 |
PF 012 (D-S-PA) P |
PFT 012 (D-S-PA) P |
10 |
15 |
50,0 |
21,3 |
34,5 |
PF 012 (D-S-PA) G |
PFT 012 (D-S-PA) G |
7 |
15 |
58,0 |
26,9 |
40,0 |
PF 034 (D-S-PA) P |
PFT 034 (D-S-PA) P |
15 |
20 |
58,0 |
26,9 |
40,0 |
PF 034 (D-S-PA) G |
PFT 034 (D-S-PA) G |
13 |
15 |
69,0 |
33,7 |
51,0 |
PF 100 (D-S-PA) P |
PFT 100 (D-S-PA) P |
15 |
22 |
69,0 |
33,7 |
51,0 |
PF 100 (D-S-PA) M |
PFT 100 (D-S-PA) M |
22 |
25 |
69,0 |
33,7 |
51,0 |
PF 100 (D-S-PA) G |
PFT 100 (D-S-PA) G |
19 |
28 |
83,0 |
42,4 |
59,5 |
PF 110 (D-S-PA) P |
PFT 110 (D-S-PA) P |
28 |
34 |
83,0 |
42,4 |
59,5 |
PF 110 (D-S-PA) G |
PFT 110 (D-S-PA) G |
19 |
28 |
99,0 |
48,3 |
72,5 |
PF 112 (D-S-PA) P |
PFT 112 (D-S-PA) P |
34 |
38 |
99,0 |
48,3 |
72,5 |
PF 112 (D-S-PA) M |
PFT 112 (D-S-PA) M |
38 |
40 |
99,0 |
48,3 |
72,5 |
PF 112 (D-S-PA) G |
PFT 112 (D-S-PA) G |
22 |
38 |
111,0 |
60,3 |
87,5 |
PF 200 (D-S-PA) P |
PFT 200 (D-S-PA) P |
38 |
47 |
111,0 |
60,3 |
87,5 |
PF 200 (D-S-PA) M |
PFT 200 (D-S-PA) M |
47 |
50 |
111,0 |
60,3 |
87,5 |
PF 200 (D-S-PA) G |
PFT 200 (D-S-PA) G |
52 |
54 |
125,0 |
76,1 |
103,5 |
PF 212 (D-S-PA) P |
PFT 212 (D-S-PA) P |
54 |
62 |
125,0 |
76,1 |
103,5 |
PF 212 (D-S-PA) G |
PFT 212 (D-S-PA) G |
52 |
54 |
125,0 |
73,0 |
103,5 |
PF 212 (D-S-PA) P |
PFT 212 (D-S-PA) P |
54 |
62 |
125,0 |
73,0 |
103,5 |
PF 212 (D-S-PA) G |
PFT 212 (D-S-PA) G |
|
|
| |
|